Failed Regulation 10 inspection? FRA action list flagging missing or painted-over strips? We supply and fit intumescent strip fitting London landlords and managing agents rely on, across East London, North London and South East London — survey-first, with a fixed quote agreed before anyone picks up a router.
- Survey-first fixed quotes
- FD30 and FD60 strip specification
- Combined intumescent and smoke seal sets
- Painted-over seal remediation
- Photographic inspection reports supplied
Inspection reports, installation records and compliance documentation are supplied as applicable to the work completed. Serving London, East London, North London, South East London, South West London and surrounding areas.
Accredited member of NAPFIS — The Home of Passive Fire Control
Intumescent Strip & Smoke Seal Fitting — at a glance
A fire door has one job: to hold back fire and smoke long enough for people to get out and for the fire to stay contained where it started. FD30 doors are tested to resist fire for 30 minutes, FD60 for 60.
- Areas covered
- London, East London, North London, South East London
- Common work
- Intumescent Strip Replacement, Cold Smoke Seal Fitting, Cold Smoke Seal Replacement, Combined Intumescent and Smoke Seal Strip
- Same-day service
- Yes
- Quote before work
- Yes — fixed price, no obligation
Quick answer
Cold smoke seal fitting stops smoke slipping past a fire door before the intumescent strip ever gets hot enough to expand. Most failures come down to perished brush pile, seals painted over during redecoration, or gaps left where a strip's been fitted but the smoke seal's missing entirely. We diagnose the leak path, fit the right profile for the door's rating, and replace what's failed - book it in rather than let an inspector flag it first.
Intumescent Strip Fitting in London: The Signs You're Missing
Intumescent strip fitting in London isn't something anyone thinks about until a fire door starts sticking, or won't sit flush in the frame any more. So what's actually gone wrong here - the door leaf, or just the seal running round the edge of it?
Nine times out of ten it's the seal. In post-war council blocks across East London and South East London, the original timber doors are often decades old, and the strip inside the groove has gone brittle, crumbled away, or dropped out entirely. In Victorian and Edwardian conversions, we regularly find flat entrance doors that were never fire-rated to begin with - so there's no groove for a strip to sit in at all. And in newer composite doors fitted post-2000, the leaf's usually fine but someone's painted straight over the smoke seal during a redecoration, which stops it expanding the way it's supposed to in heat.
None of this shows up as an emergency. That's the problem. A door with a failed seal looks and closes almost normally right up until there's smoke moving through the building, and by then it's too late to matter. Buildings over 11 metres carry routine Regulation 10 checks, but those are visual walk-rounds, not a technical fix - when a strip's damaged or missing, someone competent needs to sort it properly. For the full picture on what we cover, see London fire door services. Left alone, it only gets worse.
What Intumescent Strip Fitting in London Actually Involves
Leave a failed intumescent strip alone for another six months and you're not saving money - you're just moving the cost further down the line, usually to a point where it lands as a full doorset replacement instead of a groove-out and re-fit. A strip that's split, painted over, or missing entirely doesn't fail quietly. It fails the moment someone with a clipboard opens that door, and by then it's not a quiet fix.
The job itself varies more than people expect. Sometimes it's straightforward intumescent strip replacement on a timber FD30 flat entrance door in a post-war council block, where the original seal has perished and the self-closer's been fighting a door that no longer seats properly. Sometimes it's a composite fire door on a post-2000 development in South East London where the leaf itself is fine but nobody fitted a smoke seal at all - compliant door, non-compliant gap protection, and that's exactly the kind of thing a proper fire door survey picks up that a quick look never will. And sometimes it's a steel door on a plant room in a commercial building where the strip's been overpainted so many times it's lost its ability to expand - the intumescent material is there, it's just sealed under three coats of gloss and useless.
Spec matters more than people assume. FD30 and FD60 doors call for different strip depths and expansion rates, and getting the wrong graphite-based intumescent material fitted into the groove is as good as fitting nothing - it just takes longer to be found out. We match strip size and rating to the door's actual test evidence, not a generic default, and that includes threshold drop seals where smoke control is specified, cold smoke seal continuity across the hinge side, and glazing bead intumescent tape where the leaf has vision panels. Letterbox kits and intumescent hinge pads get missed constantly on refurbished doors - small components, same consequence if they're absent.
Our installers are individually NAPFIS-accredited, with certification kept on file for completed works and remedial sign-off where applicable. Where hinges, closers or locks turn out worn or non-rated alongside the seals, that's fire door hardware installation territory - no point fitting a new seal to ironmongery that's already failing. Get the groove routed properly, the right profile fitted, and it stops being a recurring line item on every inspection report.
London Intumescent Strip Fitting: What We Actually Do
Every job starts with a look, not a router. Before anything gets cut into a door leaf, we work out why the seal's failed - is it painted-over strip replacement that's needed, has the groove perished, or is smoke getting past a threshold that's never had a drop seal at all? Smoke leakage path diagnosis matters here, because fitting a strip in the wrong place doesn't fix a gap problem, it just hides it until the next inspection finds it again.
Once we know what we're dealing with, it's about matching the seal to the door's actual rating. FD30 door strip specification and FD60 door strip specification aren't interchangeable - a 15mm strip on a door that needs 20mm for its fire rating is a fail waiting to happen, and we've lost count of the doors across London flats and conversions where someone's fitted whatever was in the van rather than what the doorset's test evidence calls for. Compatible seal profile selection comes from the manufacturer's data, not a guess.
Groove Routing and Fitting
Where a groove needs cutting fresh, groove routing for strip installation has to follow the door's certified specification - depth, position, continuity round the frame. Hinge-side seal continuity gets missed constantly; a strip that stops short at the top hinge leaves a gap nobody notices until smoke's coming through it. We use an intumescent strip cutter to get clean, tight joins rather than the gapped, hacked-about lengths you see on a lot of DIY jobs.
Most doors get a combined intumescent and smoke seal strip fitted in one pass - the intumescent core for fire, a cold smoke seal blade alongside it for smoke that moves long before heat activates anything. Graphite-based intumescent material is standard now on most FD30 and FD60 leafs. Where the door's frame-mounted rather than door-mounted, we adjust the approach - surface-mounted strip application on some period frames, rebated fitting on others.
Finishing the Doorset
We finish with what gets missed: threshold drop seal fitting, letterbox intumescent kits, intumescent hinge pads, glazing bead intumescent tape round vision panels, rebated meeting stile seal sets on double doors. On multi-door programmes across housing association blocks, that consistency across every leaf is what separates a proper job from a patched one - and it's what a Regulation 10 check or a fuller fire door inspection remedial visit will actually be looking for.
Recognise the problem?
If one of these sounds like your situation, start there — each walks through the likely causes, how urgent it is, and the fix.
Got Painted-Over Strips or Failed Seals? Get It Booked
If your survey's already flagged gaps, perished seals or ironmongery that isn't up to spec, the next step's simple - get a proper look booked in and a written quote in hand. We cover flats and blocks across West London and North London, matching strip and seal profile to the door rating rather than guessing. Request a fire door survey and written quote and we'll take it from there.
Fire Door Seal Fitting London: Common Questions
What's the difference between an intumescent strip and a smoke seal — do I need both?
An intumescent strip sits in a groove around the door edge and stays inactive until heat hits it - then it expands to close the gap between door and frame, stopping fire getting through. A cold smoke seal does a different job entirely: it's a flexible blade or brush that blocks smoke from creeping through at room temperature, long before anything's hot enough to trigger the intumescent. Fire and smoke are separate hazards, so on a lot of doors you need both - which is exactly why combined intumescent and smoke seal strips exist, giving you one profile that handles both. Whether your door needs a fire-only strip or a combined seal depends on the doorset's test evidence and where it sits in the building. Worth getting that checked rather than guessing.
The strips around my fire door are missing or hanging off — what should I do?
A fire door without an intact strip isn't really a fire door any more - it's just a door that looks like one. Once that seal's gone, hanging loose, or shrunk back into the groove, the gap it's meant to close is sitting there open, and that gap is exactly where fire and smoke get through fastest. This is one of the quickest remedial jobs there is - usually a case of clearing the old groove, checking the size and rating match the doorset, and fitting a replacement intumescent strip fitting the door was originally specified for. If the closer's gone at the same time, that's a job for a swing-free closer fix first. Leave it and it's the first thing flagged next time anyone checks the door.
Can I fit intumescent strips myself?
You can buy strip off a shelf, sure. But getting the groove depth right, matching FD30 or FD60 strip specification to the doorset, and keeping seal continuity unbroken round hinges and meeting stiles isn't guesswork - it's routing, cutting and fitting to spec, and a strip that's the wrong size or badly seated does nothing when it matters. Doors across London's older council blocks and period conversions often have odd frame tolerances that make this trickier than it looks. If it's not right, it fails.
My strips are painted over — does that matter?
Yes. Paint bridges the strip and stops it expanding properly when it needs to. Painted-over seal remediation is one of the most common jobs we come across on inspection follow-ups - it looks fine until you look closely, and by then it's often been painted over more than once. Strip it back, check what's underneath, refit if needed.
Ready When You Are
If your doors have failed on strips, seals or both, don't let it sit on a list. Get a written quote for the work - Groove Routing, drop seal fitting, hinge pad replacement, whatever the survey turns up - before anyone touches a door in Camden, Croydon or anywhere else across the capital. Call and get it moving.